SECTION I. SUMMARY. This ordinance amends Title 7 of the County
Ordinance Code by adopting the 1988 Edition of the Uniform
Plumbing Code, as amended, as the County's plumbing code.
SECTION II. Section 78-1 .301 of the County Ordinance Code is
amended, by deleting the reference to "principal mechanical
inspector, " to read:
78-1.301 Administrative authority. The county building
inspector is the administrative authority of this division. The
term "building inspector, " unless otherwise restricted, includes
any duly authorized employee in the building inspection
department.
(Ords . 90- 18 S2, 74-29 . )
SECTION III. Chapter 78-3 of the County Ordinance Code is
repealed in its entirety, and replaced with new Chapters 78-3 and
78-5, to adopt and modify the 1988 Edition of the Uniform
Plumbing Code, to read:
CHAPTER 78-3
UNIFORM PLUMBING CODE ADOPTED
78-3.002 Adoption. (a) The plumbing code of this county
is the 1988 Edition of the Uniform Plumbing Code, published by
the International Association of Plumbing and Mechanical
Officials .
(b) This uniform code, with the changes, additions, and
deletions set forth in this division, is adopted by this
reference as though fully set forth in this division.
(c) One copy of this uniform code is on file with the
building inspection department, and the other requirements of
Government Code Section 50022. 6 have been or shall be met.
(Ords. 90- 18 §3, 80-29 §4, 74-29 . )
CHAPTER 78-5
MODIFICATIONS
Article 78-5.1
General
78-5.101 General. The 1988 Uniform ,Plumbing Code, adopted
by reference in Section 78-3 .002, shall be effective in this
county with the changes, additions and deletions set forth in
this chapter, as modified by the provisions of this division.
Where indicated.-by the context, chapter and section numbers used
in this chapter are those of the 1988 Uniform Plumbing Code
(UPC) .
(Ords . go-18 §3, 80-29 §4, 74-29 . )
78-5.103 Part 1. Part 1, Administration (pages la through
6a) , of the Uniform Plumbing Code is deleted.
(11-20-89) -1 90-18
ORDINANCE NO.
Article 78-5.2
UPC Chapter 2
78-5.203 UPC Sec. 203, copper tubing. Uniform Plumbing
Code Section 203 is amended by adding subsection (g) , as follows:
" (g) Drop-eared fittings will be installed on all fixture
and hose bib outlets, and securely fastened to adequate backing
with screws . No galvanized or ferrous pipe and/or nipples shall
be installed in a copper water system. "
(Ords . 90- 18 §3, 80-29 56, 74-29 . )
Article 78-5.3
UPC Chapter 3
78-5.318 UPC Sec. 318, inspection and testing. Uniform
Plumbing Code Section 318 is amended by adding paragraph ( 10) to
subsection (a) , as follows:
" (10) Bathtub shall be set, shower pan installed, floor
flange for water closet installed, backing for fixtures
installed, and all water piping strapped and backed before
framing insppection. "
(Ords . 90- r8 S3, 74-29 . )
Article 78-5.4
UPC Chapter 4
78-5.401 UPC Sec. 401, materials. Paragraph (2) of
subsection (a) of UPC Section 401 is amended to read:
" (2) ABS or PVC installations are limited to residential
construction, not more than two (2) stories in height. "
(Ord. go- -18 53. )
78-5.406 UPC Sec. 406, cleanouts. Uniform Plumbing Code
Section 406 is amended by adding subsection (1) , as follows:
" ( 1) All plumbing trenches under buildings shall be
backfilled. 11
(Ords . go- 18 S3, 74-29 . )
78-5.409 UPC Sec. 409, drainage. Subsection (e) of UPC
Section 409 is amended to read:
" (e) Building drains or building sewers receiving discharge
from any pump or ejector shall be adequately sized to prevent
overloading. Two fixture units shall be allowed for each gallon
per minute of continuous flow. The backwash from swimming pools,
when discharging to the sewer, shall be indirectly connected to a
four-inch P trap located on the exterior of the building on the
lower terminus '5f the main building drain. "
(Ords . 90-.18 53, 74-29 . )
Article 78-5.5
UPC Chapter 5
78-5.503 UPC Sec. 503, materials. Paragraph (2) of
subsection (a) of UPC Section 503 is amended to read:
" (2) ABS and PVC DWV piping installations are limited to
residential construction, not more than two (2) stories in
height. "
(Ord. 90- 18 S3 . )
(11-20-89) -2-
ORDINANCE NO. 9Qr18
Article 78-5.9
UPC Chapter 9
78-5.906 UPC Sec. 906, special fixtures. Uniform Plumbing
Code Section 906 is amended by adding subsection (d) , as follows:
" (d) Floor sinks. Floor sinks shall be installed with the
rim of the sink above the finished floor. No floor sink shall be
used as a combination floor drain and floor sink. "
(Ords'. 90- 18 §3, 74-29 . )
Article 78-5.10
UPC Chapter 10
78-5.1004 UPC Sec. 1004, materials. Subsection (a) of UPC
Section 1004 is amended to read:
" (a) Water pipe and fittings shall be of brass, copper, cast
iron, galvanized malleable iron, galvanized wrought iron,
galvanized steel or other approved materials. Asbestos-cement,
PE or PVC water pipe manufactured to recognized standards may be
used for cold water distribution systems outside a building. All
materials used in the water supply system, except valves and
similar devices shall be of a like material, except where
otherwise approved by the enforcement agency.
(Ord. 90- 18 § 3 . )
SECTION IV. EFFECTIVE DATE. This ordinance becomes effective 30
days after passage, and within 15 days after passage shall be
published once with the names of supervisors voting for and
against it in the Contra Costa Times, a newspaper published in
this County.
PASSED and ADOPTED on March 6 1990 , by the following vote:.
AYES: Supervisors Powers , Schroder, Torlak.-on, Fanden
NOES: None
ABSENT: Supervisor McPeak
ABSTAIN: None
ATTEST: Phil Batchelor,
Clerk of the Board of
Supervisors and County
Administrator
Deputy hair o the Board
[SEAL]
LTF: jh
df1;1tf\ord\p1umbing.f
(11-20-89) —3—
ORDINANCE
3—